9095-10132-080 (adhesive) QuickSeal Gas Perm Woven

9095-10132-080 (adhesive) QuickSeal Gas Perm Woven

QuickSeal Gas Perm Woven (adhesive seals)

Description
The seal is porous, gas permeable and a barrier to solid contaminants.

PRODUCT CODESEAL TYPEQUANTITYSIZE
9095-10132-080LRQuickSeal Gas Perm WovenRoll150M x 80mm
9095-10132-080SRQuickSeal Gas Perm Woven - SterileRoll150M x 80mm
9095-10132-080LSQuickSeal Gas Perm Woven100 sheets140mm x 80mm
9095-10132-080SSQuickSeal Gas Perm Woven - Sterile100 sheets140mm x 80mm
9095-10132-080TRQuickSeal Gas Perm WovenRoll5M x 80mm
9095-10132-080TSQuickSeal Gas Perm Woven5 sheets140mm x 80mm

Compatibility
Polypropylene (PP) Polystyrene (PS).

Application
Short term Incubation, agriculture and seed storage, Insect storage and Cell Culture.

Storage
Store in a cool place. Avoid direct exposure to sunlight. It is recommended to use the seals within three years from date of purchase. Three years when stored at 21℃(70℉), 50% relative humidity, out of direct sunlight, in original packaging.

Properties
Temperature range -20℃ to 80℃.

Sealing
Recommended sealing equipment: Ultraseal COLD-PRO.

SPECIFICATIONS
Visual Description

White Rayon Nonwoven Tape on Liner.

Physical Properties
Temperature range: -40℃ to +80℃.

TEST PROCEDURES
Mass Loss

Confirming the materials ability to resist high temperatures. Results: N/A.
Details: Mass loss of solution evaluated after 30 cycles of 3 step PCR Programme. Equipment: ABI Thermocycler, Precision Balance.

Pierce
Measuring the force required to push a standardised needle through the material via compression measuring equipment. Results: Pass.
Details 5 tests run using a standardised needle, ensuring that less than 10N is required to pierce the surface & access the wells. Equipment Instron 3343 Tensometer.

Optical
Determining the materials optical clarity by measuring the transmission of emissive dye through the material. Results N/A.
Details Record the light transmission of a sealed microplate using a Flurophore dye stock solution and a microplate reader. Equipment BMG Labtech - FluroStar.

Peel
Measuring the materials permanence of adhesion & its ability to be removed, via extension measuring equipment. Results: Pass.
Details Cohesive Failure, Adhesive Transfer, Material tear & Successful Peel are measured & recorded after a 180℃ peel test. Equipment Instron 3343 Tensometer.

Porosity Bendsten
Confirming the materials ability to breath. Results: Pass.
Details: Moisture Vapour Transmission - 4200gms/m2/24hrs.

Solvent
Evaluating the materials resistance to solvents (DMSO used as an aggressive standard) Results: N/A Details Sealed plate is subjected to a high concentration of DMSO for a time period at low temperatures after which seal damage & volume loss are determined. Equipment Laboratory Cold storage unit, DMSO solution.

Plate Types
Polypropylene (PP) Polystyrene (PS).

QC testing is carried out to ensure that products are free from nucleases (DNases & RNases) as well as human genomic DNA. Although every effort is made, including cleanroom manufacture, to maintain this level of cleanliness, best laboratory practice with regards to duplicate testing should be followed.

Kbio back button